One stator assembly
GE code 324 – model 404 (without the field)

356000KVA, 18KV, 11419 AMPS, Micapal HT insulation
Generator Stator Details: Hydrogen Gas Cooled ~ Equipment Code: 324 Model 404
2 Poles, 3 Phase, WYE Conn. 3600RPM Max H²
Pressure: 45
Rating: 356,000 KVA
Armature Amps: 11419
Armature Volts: 18,000
Field Amps: 1691
Excitation Volts: 500
Power Factor: 0.85
Insulation: Micapal HT

FORMERLY PART OF FULL STG PACKAGE:
Steam Turbine Model: 207 D-11
Rating: 301424KW 3600RPM 20 Stage LSB 33.5”
Steam Conditions:
Pressure 1812 PSIA
Temp 1050° F Exhaust Pressure 3.83” HgA

More Info | Contact us regarding this asset


 

GE D-11 340MW Reheat STG

• GE D-11 340MW Reheat STG

GE reheat steam turbine designed to work in conjunction with three GE 7FAs in a heat recovery application without supplementary firing. All equipment is new, uninstalled and unused. All equipment is under maintained storage in Houston Texas. Warranties have expired. Any new warranties will have to be negotiated directly with General Electric.

Show Details

All equipment available for immediate shipment:

D-11 Steam Turbine:
340 MW Nominal Output
1800psig inlet 1050/1050 degrees F
Model D-11 Steam turbine
40" last stage buckets
1.5" HgA exhaust pressure design

Hydrogen Cooled Generator:
410,000 kVA
0.85 Power Factor
349,350 kw
22,000 volt, 60hz

Mark VI controls
Normal auxiliaries

This Turbine was originally purchased in 2001 for use in a 3 on 1 project in New York. Although it is suitable for use in a 2 on 1 with heavy duct firing. It was stored in New York until late 2006 when it was relocated to Houston. It was inspected placed into storage and initially maintained by GE.

More Photos | Contact us regarding this asset


 

Unused GE D11
HP/IP Turbine Assembly

Other Miscellaneous parts including LP casings and 304 MW stator now available for immediate sale.

More Info | Contact us regarding this asset


 

Flared 7FA+e Compressor & Turbine Rotor

Specifications

The Unit Rotor (Compressor, R1-R17 (R0 not installed) + Turbine wheels) includes the compressor (bladed) and the turbine rotor. It is a complete (compressor and turbine) rotor with new and unused Stage 1-3 buckets.

• GE confirmed that all applicable TILs were completed during the rebuild.
• All compressor blades are new except for R0. The R0 blades are not installed.
• The Rotor is 2001 vintage.
• The Compressor is Flared.
• The Turbine Buckets are 2001 vintage.
• The TB wheel has contoured cooling holes.
• Returned to US site on 12/17/2010 from GE's Houston Service Center.

Show Details

Q & A

How many hours/starts were on the rotor when it was rebuilt?
FFH = 32,102 FS = 1,107 Actual starts = 949

Does a warranty come on the rotor?
The installed parts and workmanship of the compressor blades would be warranted at the lesser of 1 year upon installation of rotor back into a machine or 2 years upon termination of the LTSA contract.

Are all the compressor and turbine buckets new, refurbished/repaired, or combination of them?
All the installed compressor blades and R0 (standard, not enhanced) are new. The turbine buckets are new and sitting on the shelf ready for installation with the rotor.

Any test reports from the rebuild available?
YES.

More Photos | Contact us regarding this asset


Sold  

One stator assembly
GE code 324 – model 404 (without the field)

356000KVA, 18KV, 11419 AMPS, Micapal HT insulation
Generator Stator Details: Hydrogen Gas Cooled ~ Equipment Code: 324 Model 404
2 Poles, 3 Phase, WYE Conn. 3600RPM Max H²
Pressure: 45
Rating: 356,000 KVA
Armature Amps: 11419
Armature Volts: 18,000
Field Amps: 1691
Excitation Volts: 500
Power Factor: 0.85
Insulation: Micapal HT

FORMERLY PART OF FULL STG PACKAGE:
Steam Turbine Model: 207 D-11
Rating: 301424KW 3600RPM 20 Stage LSB 33.5”
Steam Conditions:
Pressure 1812 PSIA
Temp 1050° F Exhaust Pressure 3.83” HgA

More Info | Contact us regarding this asset

 

7EA Liq. Fuel Nozzle, Non-DLN
New, 10 each – 1 set

Packaged in 1 crate in good condition. 4ft W x 8ft L x 2ft H, 1260lbs. Inspected for defects and shipping damage – no defects noted. New unused condition. Installed on combustion can at factory – removed for DLN upgrade. Fuel Oil Check Valves are installed and water injection tubing on each nozzle.

Date of Manufacture: 2008 | Manufacturer: General Electric

Photo 1 | Photo 2 | Photo 3 | Photo 4 | Photo 5 | More information | Contact us regarding this part


CONTACT US


AssetAssets For Sale

For Sale: (2) General Electric 7F.05 Gas Turbine Generator Package (60Hz) HYDROGEN FUEL CAPABLE

View Assets - View Video

ONE (1) LEFT FOR SALE: GE 7EA (PG7121) DUAL LIQUID FUEL TURBINE BIOFUEL OR HYDROGEN CAPABLE

View Assets

For Sale: One GE LMS 100 60HZ Gas Turbine ONLY BOOSTER REMAINS

View Assets

Asset SearchAsset Search

Our professionals will conduct a custom search for your desired asset.

Begin Search

Global ReachMailing List

Get the latest on new equipment.

Sign up now